SCXI-1100 | SCXI电压输入模块 | ,能够实时监测电压信号的变化
型号:SCXI-1100
类别:SCXI电压输入模块
32通道,±10 V,4 Hz 滤波器,用于SCXI的电压输入模块—SCXI-1100专为毫伏、伏特和电流信号的信号调理而设计。 所有通道通过跳线选择的4 Hz低通滤波器进行多路复用,提供了多个增益范围选项。 这些通道可多路复用控制DAQ设备的单个通道中,从而增加了DAQ系统的通道数。
SCXI-1100 电压输入模块是用于接收和处理电压信号的电子组件,其设计和功能因不同的应用场景和需求而有所差异。以下是关于电压输入模块的一些主要特点和功能,参考了给出的文章信息:
通道数:SCXI-1100 电压输入模块可以具有多个模拟输入通道,例如1756-IF16A模块具有16个模拟输入通道,能够同时监测和处理多个电压信号。
电压输入范围:电压输入模块通常支持多种电压输入范围,以适应不同的应用需求。这些范围可以包括±10V、±5V、0-10V等。
分辨率:模块通常具有高分辨率,能够精确地测量电压信号,并将其转换为数字值,以便后续处理和分析。
采样率:SCXI-1100 电压输入模块通常具有较高的采样率,能够实时监测电压信号的变化,确保数据的准确性和实时性。
其他功能:
冷端补偿:一些模块支持冷端补偿功能,以校正温度变化对测量的影响。
诊断功能:模块通常具有内置的诊断功能,用于监测模块状态和性能,以及检测线路故障或异常。
模拟输出:部分模块具有模拟输出功能,可将数字控制信号转换为模拟电压输出。
Model: SCXI-1100
Brand: SCXI Voltage input module
32 channel, ±10 V, 4 Hz filter, voltage input module for SCXI- The SCXI-1100 is designed for signal conditioning of millivolt, volt, and current signals. All channels are multiplexed via a 4 Hz low-pass filter with jumper selection, providing multiple gain range options. These channels can be multiplexed to control a single channel of a DAQ device, thereby increasing the number of channels in the DAQ system.
The SCXI-1100 voltage input module is an electronic component used to receive and process voltage signals, and its design and function vary according to different application scenarios and requirements. The following are some of the main features and functions of the voltage input module, with reference to the given article information:
Number of channels: The SCXI-1100 voltage input module can have multiple analog input channels, such as the 1756-IF16A module with 16 analog input channels, capable of simultaneously monitoring and processing multiple voltage signals.
Voltage input range: Voltage input modules usually support a variety of voltage input ranges to suit different application requirements. These ranges can include ±10V, ±5V, 0-10V, etc.
Resolution: Modules typically have high resolution and are able to accurately measure voltage signals and convert them into digital values for subsequent processing and analysis.
Sampling rate: The SCXI-1100 voltage input module usually has a high sampling rate, which can monitor the change of voltage signal in real time to ensure the accuracy and real-time data.
Other features:
Cold end compensation: Some modules support cold end compensation to correct for the effect of temperature changes on the measurement.
Diagnostic functions: Modules often have built-in diagnostic functions for monitoring module status and performance, as well as detecting line faults or anomalies.
Analog output: Some modules have analog output function, which can convert the digital control signal to analog voltage output.